Home
last modified time | relevance | path

Searched hist:"4 d0df9c1e94f32a9695be352fead3167fb5135c7" (Results 1 – 3 of 3) sorted by relevance

/rk3399_rockchip-uboot/arch/arm/include/asm/arch-omap4/
H A Domap.h4d0df9c1e94f32a9695be352fead3167fb5135c7 Mon May 20 22:42:08 UTC 2013 Andrii Tseglytskyi <andrii.tseglytskyi@ti.com> OMAP3+: introduce generic ABB support

Adaptive Body Biasing (ABB) modulates transistor bias voltages
dynamically in order to optimize switching speed versus leakage.
Adaptive Body-Bias ldos are present for some voltage domains
starting with OMAP3630. There are three modes of operation:

* Bypass - the default, it just follows the vdd voltage
* Foward Body-Bias - applies voltage bias to increase transistor
performance at the cost of power. Used to operate safely at high
OPPs.
* Reverse Body-Bias - applies voltage bias to decrease leakage and
save power. Used to save power at lower OPPs.

Signed-off-by: Andrii Tseglytskyi <andrii.tseglytskyi@ti.com>
Acked-by: Nishanth Menon <nm@ti.com>
/rk3399_rockchip-uboot/arch/arm/include/asm/arch-omap5/
H A Domap.h4d0df9c1e94f32a9695be352fead3167fb5135c7 Mon May 20 22:42:08 UTC 2013 Andrii Tseglytskyi <andrii.tseglytskyi@ti.com> OMAP3+: introduce generic ABB support

Adaptive Body Biasing (ABB) modulates transistor bias voltages
dynamically in order to optimize switching speed versus leakage.
Adaptive Body-Bias ldos are present for some voltage domains
starting with OMAP3630. There are three modes of operation:

* Bypass - the default, it just follows the vdd voltage
* Foward Body-Bias - applies voltage bias to increase transistor
performance at the cost of power. Used to operate safely at high
OPPs.
* Reverse Body-Bias - applies voltage bias to decrease leakage and
save power. Used to save power at lower OPPs.

Signed-off-by: Andrii Tseglytskyi <andrii.tseglytskyi@ti.com>
Acked-by: Nishanth Menon <nm@ti.com>
/rk3399_rockchip-uboot/arch/arm/include/asm/
H A Domap_common.h4d0df9c1e94f32a9695be352fead3167fb5135c7 Mon May 20 22:42:08 UTC 2013 Andrii Tseglytskyi <andrii.tseglytskyi@ti.com> OMAP3+: introduce generic ABB support

Adaptive Body Biasing (ABB) modulates transistor bias voltages
dynamically in order to optimize switching speed versus leakage.
Adaptive Body-Bias ldos are present for some voltage domains
starting with OMAP3630. There are three modes of operation:

* Bypass - the default, it just follows the vdd voltage
* Foward Body-Bias - applies voltage bias to increase transistor
performance at the cost of power. Used to operate safely at high
OPPs.
* Reverse Body-Bias - applies voltage bias to decrease leakage and
save power. Used to save power at lower OPPs.

Signed-off-by: Andrii Tseglytskyi <andrii.tseglytskyi@ti.com>
Acked-by: Nishanth Menon <nm@ti.com>