bd2e9714 |
| 07-Dec-2016 |
Vignesh R <vigneshr@ti.com> |
regulator: fixed: Add support to handle enable-active-high DT property
Add support to handle enable-active-high DT property. This property is used to drive the gpio controlling fixed regulator as ac
regulator: fixed: Add support to handle enable-active-high DT property
Add support to handle enable-active-high DT property. This property is used to drive the gpio controlling fixed regulator as active high when claiming gpio line.
Signed-off-by: Vignesh R <vigneshr@ti.com> Acked-by: Simon Glass <sjg@chromium.org>
show more ...
|
| #
7302fbb3 |
| 22-Aug-2016 |
John Keeping <john@metanate.com> |
regulator: fixed: obey startup delay
When enabling a fixed regulator, it may take some time to rise to the correct voltage. If we do not delay here then subsequent operations will fail.
Signed-off
regulator: fixed: obey startup delay
When enabling a fixed regulator, it may take some time to rise to the correct voltage. If we do not delay here then subsequent operations will fail.
Signed-off-by: John Keeping <john@metanate.com> Reviewed-by: Tom Rini <trini@konsulko.com> Reviewed-by: Simon Glass <sjg@chromium.org>
show more ...
|
| #
9923a8b4 |
| 20-Apr-2015 |
Przemyslaw Marczak <p.marczak@samsung.com> |
dm: regulator: add fixed voltage regulator driver
This driver implements regulator operations for fixed Voltage/Current value regulators. beside the standard regulator constraints, which are put int
dm: regulator: add fixed voltage regulator driver
This driver implements regulator operations for fixed Voltage/Current value regulators. beside the standard regulator constraints, which are put into the uclass platform data, a typical fixed regulator node provides few additional properties like: - gpio - gpio-open-drain - enable-active-high - startup-delay-us The only 'gpio' is used by this driver and is kept in structure of type 'fixed_regulator_platdata', as a device platform data (dev->platdata).
The driver implements: - get_value - get_current - get_enable - set_enable
The regulator calls and commands can be used for fixed-regulator devices, and the proper error will be returned for prohibited.
Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com> Acked-by: Simon Glass <sjg@chromium.org>