xref: /OK3568_Linux_fs/kernel/drivers/thermal/intel/Kconfig (revision 4882a59341e53eb6f0b4789bf948001014eff981)
1*4882a593Smuzhiyun# SPDX-License-Identifier: GPL-2.0-only
2*4882a593Smuzhiyunconfig INTEL_POWERCLAMP
3*4882a593Smuzhiyun	tristate "Intel PowerClamp idle injection driver"
4*4882a593Smuzhiyun	depends on X86
5*4882a593Smuzhiyun	depends on CPU_SUP_INTEL
6*4882a593Smuzhiyun	help
7*4882a593Smuzhiyun	  Enable this to enable Intel PowerClamp idle injection driver. This
8*4882a593Smuzhiyun	  enforce idle time which results in more package C-state residency. The
9*4882a593Smuzhiyun	  user interface is exposed via generic thermal framework.
10*4882a593Smuzhiyun
11*4882a593Smuzhiyunconfig X86_PKG_TEMP_THERMAL
12*4882a593Smuzhiyun	tristate "X86 package temperature thermal driver"
13*4882a593Smuzhiyun	depends on X86_THERMAL_VECTOR
14*4882a593Smuzhiyun	select THERMAL_GOV_USER_SPACE
15*4882a593Smuzhiyun	select THERMAL_WRITABLE_TRIPS
16*4882a593Smuzhiyun	default m
17*4882a593Smuzhiyun	help
18*4882a593Smuzhiyun	  Enable this to register CPU digital sensor for package temperature as
19*4882a593Smuzhiyun	  thermal zone. Each package will have its own thermal zone. There are
20*4882a593Smuzhiyun	  two trip points which can be set by user to get notifications via thermal
21*4882a593Smuzhiyun	  notification methods.
22*4882a593Smuzhiyun
23*4882a593Smuzhiyunconfig INTEL_SOC_DTS_IOSF_CORE
24*4882a593Smuzhiyun	tristate
25*4882a593Smuzhiyun	depends on X86 && PCI
26*4882a593Smuzhiyun	select IOSF_MBI
27*4882a593Smuzhiyun	help
28*4882a593Smuzhiyun	  This is becoming a common feature for Intel SoCs to expose the additional
29*4882a593Smuzhiyun	  digital temperature sensors (DTSs) using side band interface (IOSF). This
30*4882a593Smuzhiyun	  implements the common set of helper functions to register, get temperature
31*4882a593Smuzhiyun	  and get/set thresholds on DTSs.
32*4882a593Smuzhiyun
33*4882a593Smuzhiyunconfig INTEL_SOC_DTS_THERMAL
34*4882a593Smuzhiyun	tristate "Intel SoCs DTS thermal driver"
35*4882a593Smuzhiyun	depends on X86 && PCI && ACPI
36*4882a593Smuzhiyun	select INTEL_SOC_DTS_IOSF_CORE
37*4882a593Smuzhiyun	select THERMAL_WRITABLE_TRIPS
38*4882a593Smuzhiyun	help
39*4882a593Smuzhiyun	  Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
40*4882a593Smuzhiyun	  temperature sensor (DTS). These SoCs have two additional DTSs in
41*4882a593Smuzhiyun	  addition to DTSs on CPU cores. Each DTS will be registered as a
42*4882a593Smuzhiyun	  thermal zone. There are two trip points. One of the trip point can
43*4882a593Smuzhiyun	  be set by user mode programs to get notifications via Linux thermal
44*4882a593Smuzhiyun	  notification methods.The other trip is a critical trip point, which
45*4882a593Smuzhiyun	  was set by the driver based on the TJ MAX temperature.
46*4882a593Smuzhiyun
47*4882a593Smuzhiyunconfig INTEL_QUARK_DTS_THERMAL
48*4882a593Smuzhiyun	tristate "Intel Quark DTS thermal driver"
49*4882a593Smuzhiyun	depends on X86_INTEL_QUARK
50*4882a593Smuzhiyun	help
51*4882a593Smuzhiyun	  Enable this to register Intel Quark SoC (e.g. X1000) platform digital
52*4882a593Smuzhiyun	  temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
53*4882a593Smuzhiyun	  The DTS will be registered as a thermal zone. There are two trip points:
54*4882a593Smuzhiyun	  hot & critical. The critical trip point default value is set by
55*4882a593Smuzhiyun	  underlying BIOS/Firmware.
56*4882a593Smuzhiyun
57*4882a593Smuzhiyunmenu "ACPI INT340X thermal drivers"
58*4882a593Smuzhiyunsource "drivers/thermal/intel/int340x_thermal/Kconfig"
59*4882a593Smuzhiyunendmenu
60*4882a593Smuzhiyun
61*4882a593Smuzhiyunconfig INTEL_BXT_PMIC_THERMAL
62*4882a593Smuzhiyun	tristate "Intel Broxton PMIC thermal driver"
63*4882a593Smuzhiyun	depends on X86 && INTEL_SOC_PMIC_BXTWC && REGMAP
64*4882a593Smuzhiyun	help
65*4882a593Smuzhiyun	  Select this driver for Intel Broxton PMIC with ADC channels monitoring
66*4882a593Smuzhiyun	  system temperature measurements and alerts.
67*4882a593Smuzhiyun	  This driver is used for monitoring the ADC channels of PMIC and handles
68*4882a593Smuzhiyun	  the alert trip point interrupts and notifies the thermal framework with
69*4882a593Smuzhiyun	  the trip point and temperature details of the zone.
70*4882a593Smuzhiyun
71*4882a593Smuzhiyunconfig INTEL_PCH_THERMAL
72*4882a593Smuzhiyun	tristate "Intel PCH Thermal Reporting Driver"
73*4882a593Smuzhiyun	depends on X86 && PCI
74*4882a593Smuzhiyun	help
75*4882a593Smuzhiyun	  Enable this to support thermal reporting on certain intel PCHs.
76*4882a593Smuzhiyun	  Thermal reporting device will provide temperature reading,
77*4882a593Smuzhiyun	  programmable trip points and other information.
78