xref: /OK3568_Linux_fs/kernel/Documentation/hwmon/inspur-ipsps1.rst (revision 4882a59341e53eb6f0b4789bf948001014eff981)
1*4882a593SmuzhiyunKernel driver inspur-ipsps1
2*4882a593Smuzhiyun===========================
3*4882a593Smuzhiyun
4*4882a593SmuzhiyunSupported chips:
5*4882a593Smuzhiyun
6*4882a593Smuzhiyun  * Inspur Power System power supply unit
7*4882a593Smuzhiyun
8*4882a593SmuzhiyunAuthor: John Wang <wangzqbj@inspur.com>
9*4882a593Smuzhiyun
10*4882a593SmuzhiyunDescription
11*4882a593Smuzhiyun-----------
12*4882a593Smuzhiyun
13*4882a593SmuzhiyunThis driver supports Inspur Power System power supplies. This driver
14*4882a593Smuzhiyunis a client to the core PMBus driver.
15*4882a593Smuzhiyun
16*4882a593SmuzhiyunUsage Notes
17*4882a593Smuzhiyun-----------
18*4882a593Smuzhiyun
19*4882a593SmuzhiyunThis driver does not auto-detect devices. You will have to instantiate the
20*4882a593Smuzhiyundevices explicitly. Please see Documentation/i2c/instantiating-devices.rst for
21*4882a593Smuzhiyundetails.
22*4882a593Smuzhiyun
23*4882a593SmuzhiyunSysfs entries
24*4882a593Smuzhiyun-------------
25*4882a593Smuzhiyun
26*4882a593SmuzhiyunThe following attributes are supported:
27*4882a593Smuzhiyun
28*4882a593Smuzhiyun======================= ======================================================
29*4882a593Smuzhiyuncurr1_input		Measured input current
30*4882a593Smuzhiyuncurr1_label		"iin"
31*4882a593Smuzhiyuncurr1_max		Maximum current
32*4882a593Smuzhiyuncurr1_max_alarm		Current high alarm
33*4882a593Smuzhiyuncurr2_input		Measured output current in mA.
34*4882a593Smuzhiyuncurr2_label		"iout1"
35*4882a593Smuzhiyuncurr2_crit		Critical maximum current
36*4882a593Smuzhiyuncurr2_crit_alarm	Current critical high alarm
37*4882a593Smuzhiyuncurr2_max		Maximum current
38*4882a593Smuzhiyuncurr2_max_alarm		Current high alarm
39*4882a593Smuzhiyun
40*4882a593Smuzhiyunfan1_alarm		Fan 1 warning.
41*4882a593Smuzhiyunfan1_fault		Fan 1 fault.
42*4882a593Smuzhiyunfan1_input		Fan 1 speed in RPM.
43*4882a593Smuzhiyun
44*4882a593Smuzhiyunin1_alarm		Input voltage under-voltage alarm.
45*4882a593Smuzhiyunin1_input		Measured input voltage in mV.
46*4882a593Smuzhiyunin1_label		"vin"
47*4882a593Smuzhiyunin2_input		Measured output voltage in mV.
48*4882a593Smuzhiyunin2_label		"vout1"
49*4882a593Smuzhiyunin2_lcrit		Critical minimum output voltage
50*4882a593Smuzhiyunin2_lcrit_alarm		Output voltage critical low alarm
51*4882a593Smuzhiyunin2_max			Maximum output voltage
52*4882a593Smuzhiyunin2_max_alarm		Output voltage high alarm
53*4882a593Smuzhiyunin2_min			Minimum output voltage
54*4882a593Smuzhiyunin2_min_alarm		Output voltage low alarm
55*4882a593Smuzhiyun
56*4882a593Smuzhiyunpower1_alarm		Input fault or alarm.
57*4882a593Smuzhiyunpower1_input		Measured input power in uW.
58*4882a593Smuzhiyunpower1_label		"pin"
59*4882a593Smuzhiyunpower1_max		Input power limit
60*4882a593Smuzhiyunpower2_max_alarm	Output power high alarm
61*4882a593Smuzhiyunpower2_max		Output power limit
62*4882a593Smuzhiyunpower2_input		Measured output power in uW.
63*4882a593Smuzhiyunpower2_label		"pout"
64*4882a593Smuzhiyun
65*4882a593Smuzhiyuntemp[1-3]_input		Measured temperature
66*4882a593Smuzhiyuntemp[1-2]_max		Maximum temperature
67*4882a593Smuzhiyuntemp[1-3]_max_alarm	Temperature high alarm
68*4882a593Smuzhiyun
69*4882a593Smuzhiyunvendor			Manufacturer name
70*4882a593Smuzhiyunmodel			Product model
71*4882a593Smuzhiyunpart_number		Product part number
72*4882a593Smuzhiyunserial_number		Product serial number
73*4882a593Smuzhiyunfw_version		Firmware version
74*4882a593Smuzhiyunhw_version		Hardware version
75*4882a593Smuzhiyunmode			Work mode. Can be set to active or
76*4882a593Smuzhiyun			standby, when set to standby, PSU will
77*4882a593Smuzhiyun			automatically switch between standby
78*4882a593Smuzhiyun			and redundancy mode.
79*4882a593Smuzhiyun======================= ======================================================