xref: /OK3568_Linux_fs/kernel/Documentation/hwmon/hih6130.rst (revision 4882a59341e53eb6f0b4789bf948001014eff981)
1*4882a593SmuzhiyunKernel driver hih6130
2*4882a593Smuzhiyun=====================
3*4882a593Smuzhiyun
4*4882a593SmuzhiyunSupported chips:
5*4882a593Smuzhiyun
6*4882a593Smuzhiyun  * Honeywell HIH-6130 / HIH-6131
7*4882a593Smuzhiyun
8*4882a593Smuzhiyun    Prefix: 'hih6130'
9*4882a593Smuzhiyun
10*4882a593Smuzhiyun    Addresses scanned: none
11*4882a593Smuzhiyun
12*4882a593Smuzhiyun    Datasheet: Publicly available at the Honeywell website
13*4882a593Smuzhiyun
14*4882a593Smuzhiyun	http://sensing.honeywell.com/index.php?ci_id=3106&la_id=1&defId=44872
15*4882a593Smuzhiyun
16*4882a593SmuzhiyunAuthor:
17*4882a593Smuzhiyun  Iain Paton <ipaton0@gmail.com>
18*4882a593Smuzhiyun
19*4882a593SmuzhiyunDescription
20*4882a593Smuzhiyun-----------
21*4882a593Smuzhiyun
22*4882a593SmuzhiyunThe HIH-6130 & HIH-6131 are humidity and temperature sensors in a SO8 package.
23*4882a593SmuzhiyunThe difference between the two devices is that the HIH-6131 has a condensation
24*4882a593Smuzhiyunfilter.
25*4882a593Smuzhiyun
26*4882a593SmuzhiyunThe devices communicate with the I2C protocol. All sensors are set to the same
27*4882a593SmuzhiyunI2C address 0x27 by default, so an entry with I2C_BOARD_INFO("hih6130", 0x27)
28*4882a593Smuzhiyuncan be used in the board setup code.
29*4882a593Smuzhiyun
30*4882a593SmuzhiyunPlease see Documentation/i2c/instantiating-devices.rst for details on how to
31*4882a593Smuzhiyuninstantiate I2C devices.
32*4882a593Smuzhiyun
33*4882a593Smuzhiyunsysfs-Interface
34*4882a593Smuzhiyun---------------
35*4882a593Smuzhiyun
36*4882a593Smuzhiyuntemp1_input
37*4882a593Smuzhiyun	temperature input
38*4882a593Smuzhiyun
39*4882a593Smuzhiyunhumidity1_input
40*4882a593Smuzhiyun	humidity input
41*4882a593Smuzhiyun
42*4882a593SmuzhiyunNotes
43*4882a593Smuzhiyun-----
44*4882a593Smuzhiyun
45*4882a593SmuzhiyunCommand mode and alarms are not currently supported.