1*4882a593Smuzhiyun* Broadcom Northstar Thermal 2*4882a593Smuzhiyun 3*4882a593SmuzhiyunThis binding describes thermal sensor that is part of Northstar's DMU (Device 4*4882a593SmuzhiyunManagement Unit). 5*4882a593Smuzhiyun 6*4882a593SmuzhiyunRequired properties: 7*4882a593Smuzhiyun- compatible : Must be "brcm,ns-thermal" 8*4882a593Smuzhiyun- reg : iomem address range of PVTMON registers 9*4882a593Smuzhiyun- #thermal-sensor-cells : Should be <0> 10*4882a593Smuzhiyun 11*4882a593SmuzhiyunExample: 12*4882a593Smuzhiyun 13*4882a593Smuzhiyunthermal: thermal@1800c2c0 { 14*4882a593Smuzhiyun compatible = "brcm,ns-thermal"; 15*4882a593Smuzhiyun reg = <0x1800c2c0 0x10>; 16*4882a593Smuzhiyun #thermal-sensor-cells = <0>; 17*4882a593Smuzhiyun}; 18*4882a593Smuzhiyun 19*4882a593Smuzhiyunthermal-zones { 20*4882a593Smuzhiyun cpu_thermal: cpu-thermal { 21*4882a593Smuzhiyun polling-delay-passive = <0>; 22*4882a593Smuzhiyun polling-delay = <1000>; 23*4882a593Smuzhiyun coefficients = <(-556) 418000>; 24*4882a593Smuzhiyun thermal-sensors = <&thermal>; 25*4882a593Smuzhiyun 26*4882a593Smuzhiyun trips { 27*4882a593Smuzhiyun cpu-crit { 28*4882a593Smuzhiyun temperature = <125000>; 29*4882a593Smuzhiyun hysteresis = <0>; 30*4882a593Smuzhiyun type = "critical"; 31*4882a593Smuzhiyun }; 32*4882a593Smuzhiyun }; 33*4882a593Smuzhiyun 34*4882a593Smuzhiyun cooling-maps { 35*4882a593Smuzhiyun }; 36*4882a593Smuzhiyun }; 37*4882a593Smuzhiyun}; 38