/rk3399_rockchip-uboot/arch/arm/cpu/arm926ejs/mxs/
H A Dspl_power_init.c7bbc5ff732bcf8d2aa935249ce4b7c28a701ca51 Thu May 21 11:20:17 UTC 2015 Stefan Wahren <stefan.wahren@i2se.com> mxs: Do not disable bo detection when DC-DC is already enabled

In case the DC-DC is already enabled mxs_enable_4p2_dcdc_input() returns
without reenabling brown out detection. So fix this issue by
moving the return before brown out deactivation.

Signed-off-by: Stefan Wahren <stefan.wahren@i2se.com>
Reviewed-by: Marek Vasut <marex@denx.de>