Lines Matching +full:input +full:- +full:only

10     Addresses scanned: -
18 Addresses scanned: -
26 Addresses scanned: -
34 Addresses scanned: -
42 Addresses scanned: -
49 Guenter Roeck <linux@roeck-us.net>
53 -----------
55 Chips in this series are multi-phase step-down converters with one or two
60 -----------
69 # echo tps53681 0x60 > /sys/bus/i2c/devices/i2c-1/new_device
73 ----------------
78 in1_input Measured input voltage.
80 in1_lcrit Critical minimum input voltage
82 TPS53679, TPS53681, TPS53688 only.
84 in1_lcrit_alarm Input voltage critical low alarm.
86 TPS53679, TPS53681, TPS53688 only.
88 in1_crit Critical maximum input voltage.
90 in1_crit_alarm Input voltage critical high alarm.
92 in[N]_label "vout[1-2]"
94 - TPS53647, TPS53667: N=2
95 - TPS53679, TPS53588: N=2,3
99 in[N]_lcrit Critical minimum input voltage.
101 TPS53679, TPS53681, TPS53688 only.
105 TPS53679, TPS53681, TPS53688 only.
109 TPS53647, TPS53667 only.
113 TPS53679, TPS53681, TPS53688 only.
117 TPS53679, TPS53681, TPS53688 only.
121 - TPS53647, TPS53667: N=1
122 - TPS53679, TPS53681, TPS53588: N=1,2
134 power1_input Measured input power.
136 power[N]_label "pout[1-2]".
138 - TPS53647, TPS53667: N=2
139 - TPS53679, TPS53681, TPS53588: N=2,3
145 curr1_input Measured input current.
147 curr1_max Maximum input current.
149 curr1_max_alarm Input current high alarm.
151 curr1_crit Critical input current.
153 curr1_crit_alarm Input current critical alarm.
155 curr[N]_label "iout[1-2]" or "iout1.[0-5]".
158 digit is the phase within the channel. Per-phase
159 telemetry supported on TPS53681 only.
161 - TPS53647, TPS53667: N=2
162 - TPS53679, TPS53588: N=2,3
163 - TPS53681: N=2-9
175 Limit and alarm attributes are only available for
176 non-phase telemetry (iout1, iout2).