Lines Matching +full:skew +full:- +full:delay

4 to clock delays. You can specify clock delay values in the PHY OF
8 Note that these settings are applied after any phy-specific fixup from
14 All skew control options are specified in picoseconds. The minimum
17 skew values actually increase in 120ps steps, starting from -840ps. The
23 The following table shows the actual skew delay you will get for each of the
25 corresponding pad skew register:
27 Device Tree Value Delay Pad Skew Register Value
28 -----------------------------------------------------
29 0 -840ps 0000
30 200 -720ps 0001
31 400 -600ps 0010
32 600 -480ps 0011
33 800 -360ps 0100
34 1000 -240ps 0101
35 1200 -120ps 0110
48 - rxc-skew-ps : Skew control of RXC pad
49 - rxdv-skew-ps : Skew control of RX CTL pad
50 - txc-skew-ps : Skew control of TXC pad
51 - txen-skew-ps : Skew control of TX CTL pad
52 - rxd0-skew-ps : Skew control of RX data 0 pad
53 - rxd1-skew-ps : Skew control of RX data 1 pad
54 - rxd2-skew-ps : Skew control of RX data 2 pad
55 - rxd3-skew-ps : Skew control of RX data 3 pad
56 - txd0-skew-ps : Skew control of TX data 0 pad
57 - txd1-skew-ps : Skew control of TX data 1 pad
58 - txd2-skew-ps : Skew control of TX data 2 pad
59 - txd3-skew-ps : Skew control of TX data 3 pad
63 All skew control options are specified in picoseconds. The minimum
64 value is 0, and the maximum is property-dependent. The increment
66 rxc-skew-ps=<0> actually results in -900 picoseconds adjustment.
72 - rxc-skew-ps : Skew control of RX clock pad
73 - txc-skew-ps : Skew control of TX clock pad
77 - rxdv-skew-ps : Skew control of RX CTL pad
78 - txen-skew-ps : Skew control of TX CTL pad
79 - rxd0-skew-ps : Skew control of RX data 0 pad
80 - rxd1-skew-ps : Skew control of RX data 1 pad
81 - rxd2-skew-ps : Skew control of RX data 2 pad
82 - rxd3-skew-ps : Skew control of RX data 3 pad
83 - txd0-skew-ps : Skew control of TX data 0 pad
84 - txd1-skew-ps : Skew control of TX data 1 pad
85 - txd2-skew-ps : Skew control of TX data 2 pad
86 - txd3-skew-ps : Skew control of TX data 3 pad
88 - micrel,force-master:
97 All skew control options are specified in picoseconds. The increment
99 A negative value can be assigned as rxc-skew-psec = <(-100)>;.
103 Range of the value -700 to 2400, default value 0:
105 - rxc-skew-psec : Skew control of RX clock pad
106 - txc-skew-psec : Skew control of TX clock pad
108 Range of the value -700 to 800, default value 0:
110 - rxdv-skew-psec : Skew control of RX CTL pad
111 - txen-skew-psec : Skew control of TX CTL pad
112 - rxd0-skew-psec : Skew control of RX data 0 pad
113 - rxd1-skew-psec : Skew control of RX data 1 pad
114 - rxd2-skew-psec : Skew control of RX data 2 pad
115 - rxd3-skew-psec : Skew control of RX data 3 pad
116 - txd0-skew-psec : Skew control of TX data 0 pad
117 - txd1-skew-psec : Skew control of TX data 1 pad
118 - txd2-skew-psec : Skew control of TX data 2 pad
119 - txd3-skew-psec : Skew control of TX data 3 pad
124 phy0: ethernet-phy@0 {
125 rxc-skew-ps = <3000>;
126 rxdv-skew-ps = <0>;
127 txc-skew-ps = <3000>;
128 txen-skew-ps = <0>;
134 phy-mode = "rgmii-id";